M items · M1800–M1870 ADL/IADL items

M1850 Transferring

Quality measures (2)
Scored in
  • Improvement in Bed Transferring
  • Stabilization in Bed Transferring

1Response codes Enter one code, 0–5 · PDGM points shown

M1850. Transferring Current ability to move safely from bed to chair, or ability to turn and position self in bed if patient is bedfast.

  • 0Able to independently transfer.0 pts
  • 1Able to transfer with minimal human assistance or with use of an assistive device.1 pt
  • 2Able to bear weight and pivot during the transfer process but unable to transfer self.4 pts
  • 3Unable to transfer self and is unable to bear weight or pivot when transferred by another person.4 pts
  • 4Bedfast, unable to transfer but is able to turn and position self in bed.4 pts
  • 5Bedfast, unable to transfer and is unable to turn and position self.4 pts

PDGM points: each response carries the points shown, which count toward the PDGM functional level. Points from M1800–M1860 are added together with M1033 (risk for hospitalization) points, and the Low, Medium and High cutoffs depend on the clinical group. Source: CMS Home Health Grouper Software v07.2.26, effective October 1, 2026.

2Rules for the M1800 ADL/IADL items Section G introduction, Chapter 3, p. 122 · Chapter 1, pp. 14–15

Section G introduction and the conventions for the M1800 ADL/IADL items
General rules · apply to the M1800 ADL/IADL items

Section G Introduction (Chapter 3, p. 122)

The items in this section address the patient’s ability to safely perform personal care activities. The items identify the patient’s ABILITY, not necessarily actual performance. “Willingness” and “adherence” are not the focus of these items. The patient must be viewed from a holistic perspective in assessing ability to perform ADLs. Ability can be temporarily or permanently limited by:

  • physical impairments (for example, limited range of motion, impaired balance)
  • emotional/cognitive/behavioral impairments (for example, memory deficits, impaired judgment, fear)
  • sensory impairments, (for example, impaired vision or pain)
  • environmental barriers.

1.5.8.2 Conventions Specific to OASIS M1800 ADL/IADL Items (Chapter 1, pp. 14–15)

  1. Report the patient’s physical and cognitive ability to perform a task. Do not report on the patient’s preference or willingness to perform a specified task.
  2. The level of ability refers to the level of assistance (if any) that the patient requires to safely complete a specified task. Assistance includes verbal cues, reminders, supervision and/or stand-by or hands-on assistance.
  3. While the presence or absence of a caregiver may impact the way a patient carries out an activity, it does not impact the assessing clinician’s ability to assess the patient to determine and report the level of assistance the patient requires to safely complete a task.
  4. Understand what tasks are included and excluded in each item and select the OASIS response based only on included tasks.
  5. If the patient’s ability varies between the different tasks included in a multi-task item, report what is true in a majority of the included tasks, giving more weight to tasks that are more frequently performed.
  6. Consider medical restrictions when determining ability. For example, if the physician/allowed practitioner has ordered activity restrictions, consider this when selecting the best response to functional items related to ambulation, transferring, bathing, etc.

3This item: M1850 OASIS-E2 Manual, Chapter 3, pp. 129–130

Manual text, verbatim

Item Intent

Identifies the patient’s ability to safely transfer from bed to chair (and chair to bed), or position self in bed if bedfast.

Time Points Item(s) Completed

Response-Specific Instructions

  • Observation/demonstration is the preferred method for coding this item.
  • The assessing clinician may also interview the patient and/or caregiver, conduct environmental assessment, and may consider available input from other agency staff who have had direct patient contact.
  • For most patients, the transfer between bed and chair will include transferring from a supine position in bed to a sitting position at the bedside, then some type of standing, stand-pivot, or sliding board transfer to a chair, and back into bed from the chair or sitting surface.
  • If there is no chair in the patient’s bedroom or the patient does not routinely transfer from the bed directly into a chair in the bedroom, report the patient’s ability to move from a supine position in bed to a sitting position at the side of the bed, and then the ability to stand and then sit on whatever surface is applicable to the patient’s environment and need, (for example, a chair in another room, a bedside commode, the toilet, a bench, etc.). Include the ability to return back into bed from the sitting surface.
  • The patient’s ability may change as the patient’s condition improves or declines, as medical restrictions are imposed or lifted, or as the environment is modified. The clinician must consider what the patient is able to do on the day of the assessment. If ability varies over time, enter the response describing the patient’s ability more than 50% of the time period under consideration.
  • Able to bear weight refers to the patient’s ability to support the majority of their body weight through any combination of weight-bearing extremities (for example, a patient with a weight-bearing restriction of one lower extremity may be able to support their entire weight through the other lower extremity and upper extremities).
  • Bedfast refers to being confined to the bed, either per physician restriction or due to a patient’s inability to tolerate being out of the bed.

Coding Instructions

  • Code 1, if the patient:
    • Transfers either with minimal human assistance (but not a device), or with the use of a device (but no human assistance).
  • Code 2, if the patient:
    • Requires both minimal human assistance AND an assistive device to transfer safely.
    • Can both bear weight and pivot but requires more than minimal human assistance.
  • Code 3, if the patient is unable to bear weight or pivot and is not bedfast.
  • Dash is not a valid response for this item.

Coding Tips

  • “Minimal human assistance” applies when the helper is contributing less than 25% of the total effort required to complete the task.
  • Assistance may include any combination of verbal cueing, environmental set-up, and/or actual hands-on assistance.

The manual gives no Examples for M1850.

4CMS Q&As for M1850 18 active

How tagging works: each Q&A is matched to items automatically from the item IDs in its heading. 12 name M1850 directly and 6 cover a whole group of items. Entries stay marked “awaiting review” until checked. CMS notes Q&A answers “may be time-limited and may be superseded.”

Name M1850 directly 12

CMS Q&A
Cat. 4b, Q148.2 ActiveTagging: best guess, awaiting review

Question

M1840 & M1850. Regarding M1840 - Toilet Transferring Response 1 (reminded, assisted, or supervised by another person) & M1850 - Transferring Response 1 (minimal human assistance or with assistive device), what exactly do the terms “assisted” & “minimal human assistance” mean? In the therapy world, minimal assistance means the caregiver must provide less than 25% of the effort required to assist the patient in completing the task safely. Is this what the clinician is supposed to look at or could minimal human assistance mean verbal cueing or stand by assist only?

Show answerHide answer

Answer

The current OASIS Guidance Manual, Chapter 1 Conventions explains " When an OASIS item refers to assistance, this means assistance from another person. Assistance is not limited to physical contact and can include necessary verbal cues and/or supervision." When completing M1840, Toilet Transferring, if the patient can participate, but requires any degree of hands-on assistance and/or standby assistance and/or verbal cueing/reminders to get to/from the toilet and/or transfer on/off the toilet safely, select Response 1. An example of Response 1 could be a patient who requires verbal cues regarding safe use of walker while ambulating to the toilet.

When completing M1850, Transferring, minimal human assistance referenced in Response 1 would include a minimal degree of any combination of verbal cueing, environmental set-up and/or actual hands-on assistance. In order for the assistance to be considered minimal, it would mean the individual assisting the patient is contributing less than 25% of the total effort required to perform the transfer.

An example of Response 1 could be a patient that requires hands-on assistance during the change in position from supine to sitting at the edge of bed, where the effort contributed by the individual assisting is less than 25% of total effort required to perform the transfer.

Applies to: M1840 · M1850

History: [Q&A EDITED 10/23; EDITED 05/22; EDITED 06/14; ADDED 01/11; Previously CMS OCCB Q&A 04/10 Q19] · Source: CMS OASIS Q&As, Category 4b, pp. 67–68.

CMS Q&A
Cat. 4b, Q150.1 ActiveTagging: best guess, awaiting review

Question

M1850. When completing M1850 - Transferring, do I consider the patient’s gait impairment if they must ambulate 12 feet from the bed to get to the closest sitting surface and the need for assistance of another person?

Show answerHide answer

Answer

The need for assistance with gait may impact the M1850 - Transferring score if the closest sitting surface applicable to the patient's environment is not next to the bed. M1850 reports the patient's ability to move from the supine position in bed (or the current sleeping surface) to a sitting position at the bedside, then some type of standing, stand-pivot, or sliding board transfer to a sitting surface at the bedside. If there is no chair at the bedside, report the ability to transfer from the sleeping surface to whatever sitting surface is applicable to the patient's environment and need. If the sleeping surface is in the bedroom and the sitting surface is down the hall in the bathroom and the patient is independent moving from the supine to sitting position, sitting to standing, and then standing to sitting, but requires minimal human assistance or an assistive device to ambulate from the bed to the sitting surface, the appropriate M1850 score would be a "1". If the patient requires more than minimal assistance or requires both minimal human assistance and an assistive device to be safe, the appropriate score would be response 2.

Applies to: M1850

History: [Q&A EDITED 12/12; ADDED 01/12; Previously CMS OCCB Q&A 10/11 Q9] · Source: CMS OASIS Q&As, Category 4b, p. 68.

CMS Q&A
Cat. 4b, Q151.1 ActiveTagging: best guess, awaiting review

Question

M1850. When scoring M1850 - Transferring, response 1 indicates that that patient requires minimal human assistance or the use of an assistive device to safely transfer. What constitutes an “assistive device” for the purposes of differentiating “truly independent” transferring (response 0) from “modified independent” transferring (response 1 or transferring with equipment)?

Show answerHide answer

Answer

CMS does not provide a definitive list of assistive devices to apply when determining relevant OASIS responses. Use your clinical judgment and examples of devices included in OASIS items and related Q&As in determining what are considered assistive devices when scoring OASIS items.

Applies to: M1850

History: [Q&A EDITED 05/22; EDITED 01/12; ADDED 08/07; Previously CMS OCCB Q&A 08/04 Q16] · Source: CMS OASIS Q&As, Category 4b, pp. 68–69.

CMS Q&A
Cat. 4b, Q151.3 ActiveTagging: best guess, awaiting review

Question

M1850. A quadriplegic is totally dependent, cannot even turn self in bed, however, they do get up to a gerichair by Hoyer lift. For M1850 - Transferring, is the patient considered bedfast?

Show answerHide answer

Answer

A patient who can tolerate being out of bed is not “bedfast.” If a patient is able to be transferred to a chair using a Hoyer lift, Response 3 is the option that most closely resembles the patient’s circumstance; the patient is unable to transfer and is unable to bear weight or pivot when transferred by another person. Because the patient is transferred to a chair, they would not be considered bedfast (“confined to the bed”) even though they cannot help with the transfer. Responses 4 and 5 do not apply for the patient who is not bedfast. The frequency of the transfers does not change the response, only the patient’s ability to be transferred and tolerate being out of bed.

Applies to: M1850

History: [Q&A EDITED 10/23; EDITED 05/22; ADDED 08/07; M item updated 09/09; Previously CMS OCCB Q&A 05/07 Q29] · Source: CMS OASIS Q&As, Category 4b, p. 69.

CMS Q&A
Cat. 4b, Q151.4 ActiveTagging: best guess, awaiting review

Question

M1850. How do you select a score for M1850 - Transferring, for the patient who is not really safe at response 1, but moving to response 2 seems a bit aggressive? Response 1 uses the word "or" NOT "and". If a patient requires both human assist AND an assistive device, does this move them to response 2, especially if they are not safe? It seems these patients can do more than bear weight and pivot--but it is the next best option. If they require human assist AND an assistive device, should we automatically move the patient to a response 2, whether they are safe or not?

Show answerHide answer

Answer

If the patient is able to safely transfer with either minimal human assistance (but no device), or with the use of an assistive device (but no human assistance) then they should be reported as a 1 - Able to transfer with minimal human assistance or with use of an assistive device. If the assessing clinician determines the patient is not safe in transferring with either of the above circumstances, (e.g., they transfer with only an assistive device but not safely, minimal assistance only is not adequate for safe transferring, or they require both minimal human assistance and an assistive device to transfer safely), then the patient would be scored a 2 - Able to bear weight and pivot during the transfer process but unable to transfer self (assuming the patient could bear weight and pivot). Safety is integral to ability. If the patient is not safe when transferring with just minimal human assistance or with just an assistive device, they cannot be considered functioning at the level of Response 1.

For the purposes of Response 1, minimal human assistance could include any combination of verbal cueing, environmental set-up, and/or actual hands-on assistance, where the level of assistance required from someone else is equal to or less than 25% of the total effort to transfer and the patient is able to provide >75% of the total effort to complete the task. Examples of environmental set-up as it relates to transferring would be a patient who requires someone else to position the wheelchair by the bed and apply the wheelchair locks in order to safely transfer from the bed to the chair, or a patient who requires someone else to place the elevated commode seat over the toilet before the patient is able to safely transfer onto the commode.

Applies to: M1850

History: [Q&A EDITED 05/22; ADDED 08/07; M number updated 09/09; Previously CMS OCCB Q&A 07/07 Q15] · Source: CMS OASIS Q&As, Category 4b, p. 69.

CMS Q&A
Cat. 4b, Q151.6 ActiveTagging: best guess, awaiting review

Question

M1850. When scoring M1850 - Transferring, the assessment revealed difficulty with transfers. The patient was toe touch weight bearing on the left lower extremity and had pain in the opposite weight bearing hip. The patient had a history of falls and remained at risk due to medication side effects, balance problems, impaired judgment, weakness, unsteady use of device and required assistance to transfer. The concern is the safety of the transfers considering all of the above. Would response 2 or response 3 be the appropriate response?

Show answerHide answer

Answer

Safety is integral to ability, if the assessing clinician determines the patient requires more than minimal human assistance or they need minimal assistance and an assistive device to safely transfer, and can bear weight and pivot safely, Response 2 should be reported. If the assessing clinician determines the bearing weight and pivoting component of the transfer is not safe even with assistance, then the patient is not able to bear weight or pivot and the appropriate selection would be Response 3 – Unable to transfer self and is unable to bear weight or pivot when transferred by another person.

Applies to: M1850

History: [Q&A EDITED 05/22; ADDED 09/09; M item updated 09/09; Previously CMS OCCB Q&A 10/07 Q22] · Source: CMS OASIS Q&As, Category 4b, p. 70.

CMS Q&A
Cat. 4b, Q151.6.1 ActiveTagging: best guess, awaiting review

Question

M1850. When answering M1850 - Transferring, do the responses that reference weight bearing and pivoting include an individual that uses a sliding board and would be weight bearing and pivoting using only the upper extremities, not the lower?

Show answerHide answer

Answer

The term "bear weight and pivot" in M1850, Transferring, may include both a standing pivot transfer and multiple sitting pivot transfers, such as those utilized when performing a bed-to-chair transfer with a sliding board.

If the patient does not have use of the lower extremities and transfers with the use of a sliding board, but no human assistance, select Response 1 - Able to transfer with minimal human assistance or with use of an assistive device. If the patient requires both minimal human assistance and the sliding board to transfer safely, select Response 2 - Able to bear weight and pivot during the transfer process but unable to transfer self. If the patient can bear weight and pivot utilizing their upper extremities, but requires more than minimal human assist, Response 2 should be marked. The patient must be able to both bear weight and pivot for Response 2 to apply. If the patient is unable to do one or the other and is not bedfast, select Response 3 - Unable to transfer self and is unable to bear weight or pivot when transferred by another person.

Applies to: M1850

History: [Q&A ADDED 06/14; Previously CMS Qtrly Q&A 07/13 Q15] · Source: CMS OASIS Q&As, Category 4b, p. 70.

CMS Q&A
Cat. 4b, Q151.7 ActiveTagging: best guess, awaiting review

Question

M1850. For M1850 - Transferring, does the transfer from bed to chair include evaluation from a seated position in bed to a seated position in a chair or from supine in bed to seated in a chair?

Show answerHide answer

Answer

The bed to chair transfer includes the patient's ability to get from the bed to a chair and from the chair back into bed. For most patients, this will include transferring from a supine position in bed to a sitting position at the bedside, then some type of standing, stand-pivot, or sliding board transfer to a chair.

Applies to: M1850

History: [Q&A ADDED 09/09; EDITED 01/10; Previously CMS OCCB Q&A 07/08 Q15] · Source: CMS OASIS Q&As, Category 4b, p. 70.

CMS Q&A
Cat. 4b, Q151.7.1 ActiveTagging: best guess, awaiting review

Question

M1850. Is M1850 - Transferring assessed for the patient who has slept for years in a recliner?

Show answerHide answer

Answer

M1850 - Transferring, must be assessed for all patients requiring OASIS data collection. The item includes assessment of the bed to chair/chair to bed transfers. If your patient no longer sleeps in a bed (e.g., sleeps in a recliner or on a couch), you will assess the patient's ability to move from the supine position on their current sleeping surface to a sitting position and then transfer to another sitting surface, like a bedside commode, bench, or chair, and then back to their current sleeping surface.

Applies to: M1850

History: [Q&A EDITED 05/22; EDITED 12/12; ADDED 01/11; Previously CMS OCCB Q&A 01/10 Q13] · Source: CMS OASIS Q&As, Category 4b, pp. 70–71.

CMS Q&A
Cat. 4b, Q151.7.2 ActiveTagging: best guess, awaiting review

Question

M1850. How do we score M1850 - Transferring, when the patient is temporarily sleeping in the recliner because there is a physician’s order not to climb stairs and the patient’s bed is located on the second floor?

Show answerHide answer

Answer

In the situation described, the medical restriction against climbing stairs does not impact the patient's ability. The assessing clinician will report the patient's ability to move from the supine position on the current sleeping surface to a sitting position at the side of the sleeping surface, then some type of standing, stand-pivot, or sliding board transfer to a sitting surface, and then back to their current sleeping surface.

Certain medical restrictions could impact ability, e.g., an order to maintain strict bed rest means the patient is scored as bedfast. Other medical restrictions that may prevent access to the usual sleeping surface DO NOT impact ability as M1850 – Transferring reports the patient's ability to move from the bed or current sleeping surface, e.g., an order not to climb stairs or an order to sleep in hospital bed.

Applies to: M1850

History: [Q&A EDITED 05/22; ADDED 06/14; Previously CMS Qtrly Q&A 04/13 Q6] · Source: CMS OASIS Q&As, Category 4b, p. 71.

CMS Q&A
Cat. 4b, Q151.14 ActiveTagging: best guess, awaiting review

Question

M1850 & M1860. How is “bedfast” defined for M1850 - Transferring and M1860 - Ambulation/Locomotion? Do I only count what my patient could do during the visit?

Show answerHide answer

Answer

M1850 - Transferring and M1860 - Ambulation/Locomotion report the patient's ability on the day of the assessment. Day of assessment is the 24 hours immediately preceding the visit and the time spent in the home. Ch. 3 of the current OASIS Guidance Manual in the M1850 Response-Specific Instructions defines bedfast. "Bedfast refers to being confined to the bed, either per physician restriction or due to a patient's inability to tolerate being out of the bed." If the patient can tolerate being out of bed, they are not bedfast unless they are medically restricted to the bed. The patient is not required to be out of bed for any specific length of time. The assessing clinician will have to use their judgment when determining whether or not a patient can tolerate being out of bed. For example, a severely deconditioned patient may only be able to sit in the chair for a few minutes and is not considered bedfast as they are able to tolerate being out of bed. A patient with Multiple System Atrophy becomes severely hypotensive within a minute of moving from the supine to sitting position and is considered bedfast due to the neurological condition which prevents them from tolerating the sitting position.

Applies to: M1850 · M1860

History: [Q&A EDITED 05/22; EDITED 06/14; ADDED 01/12; Previously CMS OCCB Q&A 04/11 Q10] · Source: CMS OASIS Q&As, Category 4b, p. 71.

CMS Q&A
Cat. 4b, Q155.4 ActiveTagging: best guess, awaiting review

Question

M1840, M1850 & M1860. Is it true that when the word "OR" appears in a question and the patient's condition meets both sides of the statement that the patient should automatically be marked at the next level down on the scale? Also, if the patient is marked as a "3" on M1860, Ambulation, can the patient be a "0" independent in toileting transferring?

Show answerHide answer

Answer

When scoring the OASIS, clinicians should avoid applying "always", "never", or "automatically" rules. Each item, the response options contained in the item, and additional available guidance in the form of Q&As and from Chapter 3 should be reviewed and the most accurate response should be selected. It is not a universally true statement to say that if conditions on both sides of the word "OR" pertain to the patient, then the patient should be automatically scored at the next level down. For instance, Response 0 for M1830 - Bathing says, "Able to bathe self in shower or tub independently, including getting in and out of tub/shower”. If the patient was able to bathe in the shower independently AND also able to bathe in the tub independently, it would not be appropriate to score them at the next level down simply because conditions on both sides of the word "OR" are met.

When scoring M1860 - Ambulation/Locomotion, response option 3 is selected when the patient requires human supervision or assistance at all times in order to ambulate safely. Response 0 is selected if the patient requires no human assistance and no assistive devices to ambulate safely on even and uneven surfaces. All other combinations of needing assistance intermittently are reported as 2.

For M1850 - Transferring, Response 1 - Able to transfer with minimal human assistance or with use of an assistive device, it is true that if the patient requires BOTH minimal human assistance AND an assistive device to transfer safely, then the response option 2 should be selected (See CMS OASIS Q&A Category 4b Questions 151.4.) If a patient requires constant human supervision or assistance in order to ambulate safely, they are scored a 3 for M1860 - Ambulation/Locomotion. A patient can only be scored a 0 for M1840, Toilet Transferring, if they can get to and from the toilet and transfer independently with or without a device. It would be possible for a patient to be a "3" for M1860, Ambulation/Locomotion and also be reported as a "0" for M1840, Toilet Transferring, if the patient required assistance at all times to ambulate but was able to get to and from the toilet and transfer safely and without assistance using a wheelchair.

Applies to: M1840 · M1850 · M1860

History: [Q&A ADDED & EDITED 09/09; Previously CMS OCCB Q&A 01/08 Q21] · Source: CMS OASIS Q&As, Category 4b, p. 75.

Cover the M1800–M1870 function items in general 6

CMS Q&A
Cat. 4b, Q127.1 ActiveTagging: best guess, awaiting review

Question

M1800 - M1870. Are service animals considered a form of assistance?

Show answerHide answer

Answer

If required for a patient’s safe function, service animals should be considered an assistive device for purposes of selecting responses to the OASIS items. Service animals should not be equated to human assistance (e.g., “someone must assist…”)

Applies to: M1800–M1870 (includes M1850)

History: [Q&A EDITED & ITEM NUMBER UPDATED 05/22; ADDED 01/11; Previously CMS OCCB Q&A 10/09 Q27] · Source: CMS OASIS Q&As, Category 4b, p. 56.

CMS Q&A
Cat. 4b, Q127.2.1 · also listed as Q192 ActiveTagging: best guess, awaiting review

Question

M1800s, GG0130, & GG0170. Should we expect to see consistency between a patient’s OASIS “M” and “GG” function codes?

Show answerHide answer

Answer

Not necessarily. There are differences between items that have the same or similar names. Coding differences may be a result of:

  • What is included or excluded in the activity, or
  • What coding instructions apply to the activity Each OASIS item should be considered individually and coded based on guidance specific to that item.

Applies to: M1800s (includes M1850) · GG0130 · GG0170

History: [Q&A ADDED 05/22; Previously CMS Qtrly Q&A 04/19 Q9] · Source: CMS OASIS Q&As, Category 4b, p. 56.

CMS Q&A
Cat. 4b, Q127.2.2 · also listed as Q192.1 ActiveTagging: best guess, awaiting review

Question

M1800s, GG0130, & GG0170. Can you please provide clarification for the following situation? Many of my patients are identified by the MAHC-10 as “at risk for falls”. An outsource coding company our agency uses has directed us that any patient that is scored as a fall risk on the MAHC-10 must be coded as requiring at least supervision for the function items (M1800s and GG). This instruction doesn’t always seem to be consistent with general assessment observations, and if also used at discharge, limits the ability to show improvement my patients have made. Is there some specific instruction that has been provided that requires this directed coding?

Show answerHide answer

Answer

Identifying that a patient is at risk for falls is only one criterion to consider when determining the type and amount of assistance needed for a patient to safely complete functional activities. There is no CMS guidance that requires that a patient scored as "at risk" for falls must be coded as needing supervision (or greater assistance) for any or all of the function OASIS items. Although a patient may meet the MAHC-10’s “at risk for falls” threshold, (e.g., due to age, 3+ diagnoses, age-related vision impairment, and polypharmacy), additional assessment findings (like the patient wears glasses to correct vision impairment, and sits while completing dressing activities) may allow the patient to safely complete some activities without supervision or assistance.

Even if a patient is determined to be at risk for falls, each OASIS item should be considered individually and coded based on the item specific guidance and OASIS conventions that apply to each item.

Applies to: M1800s (includes M1850) · GG0130 · GG0170

History: [Q&A ADDED 05/22; Previously CMS Qtrly Q&A 01/20 Q6] · Source: CMS OASIS Q&As, Category 4b, pp. 56–57.

CMS Q&A
Cat. 4b, Q127.3 ActiveTagging: best guess, awaiting review

Question

M1800 - M1870. About M1800 - M1870: I don’t understand the difference between “willingness” and “adherence” (which do not impact OASIS scoring) and “cognitive/mental/emotional/behavioral impairment” (which may impact OASIS scoring). For instance, if a person is unwilling to bathe appropriately, resulting in poor hygiene, an offensive odor and increased risk for infection, isn’t the patient suffering from some sort of cognitive, mental, behavioral or emotional problem that would cause this unwillingness and non-adherence? It seems that such unwillingness is a symptom of a deeper psychological problem. Please clarify.

Show answerHide answer

Answer

In absence of pathology, patients may make decisions about how and when they perform their activities of daily living that may differ from what the clinician determines to be acceptable. A patient may choose to shave and brush their teeth infrequently because they don’t value doing it at a frequency that the clinician deems as socially appropriate. There are differences in the frequency at which grooming or bathing is performed, or expected to be performed based on age, religion, culture and familial practices, and this is not necessarily indicative of pathology.

A patient may demonstrate that they can safely ambulate while using a walker, but then as a matter of choice, decide to walk without it. Another patient may demonstrate that they can safely ambulate while using a walker, but then consistently walk without it, forgetting that they have a walker. For the purposes of OASIS scoring, non-conformity or non-adherence should not automatically be considered indicative of a deeper psychological impairment. The assessing clinician will have to use clinical judgment to determine if the patient’s actions are more likely related to impairment, or to personal choice made in awareness of the potential related risk.

Applies to: M1800–M1870 (includes M1850)

History: [Q&A EDITED 10/23; EDITED & ITEM NUMBER UPDATED 05/22; EDITED 06/14; ADDED 01/11; Previously CMS OCCB Q&A 07/10 Q13] · Source: CMS OASIS Q&As, Category 4b, p. 57.

CMS Q&A
Cat. 4b, Q127.4 ActiveTagging: best guess, awaiting review

Question

M1800 - M1870. When the M item response states "assisted or supervised by another person" is that referring to a single person?

Show answerHide answer

Answer

The response related to "assistance of another person" includes those patients needing assistance of one or more person(s) to safely complete included tasks.

Applies to: M1800–M1870 (includes M1850)

History: [Q&A EDITED AND ITEM NUMBER UPDATED 05/22; ADDED 01/12; Previously CMS OCCB Q&A 07/11 Q11] · Source: CMS OASIS Q&As, Category 4b, p. 57.

CMS Q&A
Cat. 4b, Q127.5 ActiveTagging: best guess, awaiting review

Question

M1800 - M1870. My staff are confused about when a patient's ability to access the location and/or implements needed to complete the M function items should be considered when scoring the OASIS. For instance, should I include a patient's ability to get to the tub for M1830 - Bathing, or to get to the kitchen to eat for M1870 - Feeding or Eating?

Show answerHide answer

Answer

The OASIS M function items consider the patient’s ability to access the needed items and/or location where the task is performed unless item guidance specifically excludes these from consideration. The M function items where there are exclusions are:

M1830, Bathing - The focus is on the patient's ability to access the tub/shower, transfer in and out, and bathe the entire body once the needed items are within reach. The ability to access bathing supplies and prepare the water in the tub/shower are excluded from consideration when assessing the patient's bathing ability.

M1845, Toileting Hygiene - The focus is on the patient's ability to access needed supplies and implements and manage hygiene and clothing once at the location where toileting occurs. The ability to access the toilet or bedside commode, transfer on and off the bedpan and to use the urinal are excluded from consideration when assessing the patient's toileting hygiene ability. M1870, Feeding/Eating - The focus is on the patient's ability to eat, chew and swallow once the meal is placed in front of the patient and needed items are within reach. The ability to access the location where the meal is prepared and consumed, and transporting food to the table are excluded from consideration when assessing the patient's feeding/eating ability.

Applies to: M1800–M1870 (includes M1850)

History: [Q&A EDITED 05/22; EDITED 10/18; ADDED & EDITED 06/14; Previously CMS Qtrly Q&A 04/13 Q7] · Source: CMS OASIS Q&As, Category 4b, pp. 57–58.