GG items · GG0110 Prior Device Use

GG0110 Prior Device Use

Item use
Risk Adjustment
Collected at
SOC ROC FU/RCT TRN DC DAH

1Response codes Check all that apply

GG0110. Prior Device Use Check all that apply.

  • AManual wheelchair
  • BMotorized wheelchair and/or scooter
  • CMechanical lift
  • DWalker
  • EOrthotics/prosthetics
  • ZNone of the above
  • –No information (dash is a valid response for this item)

2This item: GG0110 OASIS-E2 Manual, Chapter 3, pp. 134–135

Manual text, verbatim

Item Intent

This item identifies the patient’s use of devices and aids immediately prior to the most recent illness, exacerbation, or injury.

Time Points Item(s) Completed

Start of Care Resumption of Care

Response-Specific Instructions

  • Ask the patient and/or family/caregiver, or review the clinical record, for details describing the patient’s use of prior devices and aids.
  • Report the devices used by the patient prior to the onset of the current illness, exacerbation of a chronic condition, or injury, whichever is more recent, that initiated this episode of care.
  • Check all devices that apply.
  • For the response categories in GG0110 (e.g., Mechanical lift, Orthotics/Prosthetics), CMS does not provide an exhaustive list of assistive devices that may be used when coding prior device use. Clinical judgment may be used to determine whether other devices meet the definition provided.
  • Devices may have been used indoors and/or outdoors.

Coding Instructions

  • GG0110C, Prior Devices: Mechanical lift includes any mechanical device or equipment a patient or caregiver requires for lifting or supporting the patient’s bodyweight. Examples include, but are not limited to: Stair lift, Hoyer lift, bathtub lift, sit-to-stand lift, stand assist, electric recliner, and full-body style lifts, if required.
    • Clinical judgment may be used to determine whether other devices meet the mechanical lift definition provided.
  • GG0110D, Walker refers to all types of walkers. Examples include but are not limited to pick-up walkers, hemi-walkers, rolling walkers, and platform walkers.
  • Code Z, None of the above, if the patient did not use any of the listed devices or aids immediately prior to the current illness, exacerbation, or injury.
  • Dash is a valid response for this item.
    • A dash indicates “no information.” CMS expects dash use to be a rare occurrence.

Examples

1. The patient is a bilateral lower extremity amputee and has multiple diagnoses, including diabetes, obesity, and peripheral vascular disease. They are unable to walk and did not walk prior to the current episode of care, which started because of a pressure ulcer and respiratory infection. They used a motorized wheelchair to mobilize.

  • Coding: GG0110B, Motorized wheelchair and/or scooter would be checked.
  • Rationale: The patient used a motorized wheelchair prior to the current illness/injury.

2. The patient has bilateral lower extremity neuropathy secondary to diabetes. Prior to this current home health admission, they used a cane. Today, they are using a walker.

  • Coding: GG0110Z, None of the above, would be checked.
  • Rationale: A cane is not a device included in the list of devices in GG0110. Not all devices and aids are included in this item.

3CMS Q&As for GG0110 3 active

How tagging works: each Q&A is matched to items automatically from the item IDs in its heading. 1 name GG0110 directly and 2 cover a whole group of items. Entries stay marked “awaiting review” until checked. CMS notes Q&A answers “may be time-limited and may be superseded.”

Name GG0110 directly 1

CMS Q&A
Cat. 4b, Q250 ActiveTagging: best guess, awaiting review

Question

GG0110D & GG0170. When responding to GG items, would a knee scooter/walker be considered a walker or a scooter? The product is sold under and referenced by both titles.

Show answerHide answer

Answer

For GG0110D - Prior Device Use - Walker: “Walker” refers to all types of walkers (for example, pickup walkers, hemi-walkers, rolling walkers, and platform walkers), and would include a knee walker.

A knee walker/scooter would not be considered as a wheelchair/scooter for GG0170Q - Does the patient use a wheelchair and/or scooter?.

Applies to: GG0110D · GG0170

History: [Q&A ADDED 05/22; Previously CMS Qtrly Q&A 04/19 Q2] · Source: CMS OASIS Q&As, Category 4b, p. 107.

Cover GG0130 and GG0170 items in general 2

CMS Q&A
Cat. 4b, Q200 ActiveTagging: best guess, awaiting review

Question

GG0110. Since GG0110C - Prior Device Use; Mechanical lift includes “any device a patient or caregiver requires for lifting or supporting the patient’s body weight,” does this mean a gait belt is included since it is a device that a caregiver could require for lifting or supporting a patient’s body weight?

Show answerHide answer

Answer

No - this item is intended to refer to mechanical devices or equipment such as a Hoyer lift or stair lift that involve some type of machine required for lifting or supporting the patient’s body weight.

Applies to: GG0110

History: [Q&A ADDED 05/22; Previously CMS Qtrly Q&A 01/20 Q11] · Source: CMS OASIS Q&As, Category 4b, p. 107.

CMS Q&A
Cat. 4b, Q200.1 ActiveTagging: best guess, awaiting review

Question

GG0110. Should a transport chair be considered a “wheelchair” for GG0110 - Prior Device Use?

Show answerHide answer

Answer

The intent of GG0110 - Prior Device Use is to indicate which devices and aids were used by the patient prior to the current illness, exacerbation, or injury. The assessing clinician must consider each patient’s unique circumstances and use clinical judgment to determine how prior device use applies for each individual patient.

For the response categories in GG0110 (e.g., Mechanical lift, wheelchair), CMS does not provide an exhaustive list of assistive devices that may be used when coding prior device use.

Applies to: GG0110

History: [Q&A ADDED 05/22; Previously CMS Qtrly Q&A 01/21 Q4] · Source: CMS OASIS Q&As, Category 4b, p. 107.